Tel:86-0755-27266729 
 
              Fax:86-0755-27266486 
 
              Mobile:86-18922863765 
 
              Q  Q:3393844152 
              Email:1034236728@qq.com 
              Web:http://en.xiangminyiqi.com            
               
            
 Horizontal Power Battery Acupuncture Test Machine

Product Details
Product Details
1. Main Function
The test shall be carried out at an ambient temperature of 20 °C ± 5 °C. The battery with the thermocouple (the contact of the thermocouple is fixed on the large surface of the battery) shall be placed in a fume hood with a high temperature resistant steel needle with a diameter of 3-8 mm. Pierce the center of the largest surface of the battery at a speed of 10mm/s to 40mm/s and keep it at any time.
2. Standard
SJ/T11170-1998,
UL2054:1997,
GB/T18287-2000,
QC/T 743-2006,
SAND2005-3123
3. Technical Parameter
| Model | XM-DC004 | 
| High temperature resistant needle | Φ3/8mm (2 sets) steel or tungsten needle | 
| Distance between the tip and the battery | 800MM | 
| Clip distance | 300MM | 
| Acupuncture speed | 10~40mm/s(adjustable) | 
| Timer | 0-99.99H/M/S | 
| Penetration force | 1000KG | 
| Clamping method | Manual clamping (infinite direction) | 
| Itinerary | 450mm | 
| Drive mode | motor drive, use steel needle with set diameter, pierce the battery according to the set speed, and keep it at any time. | 
| Control chamber size | 800×300×300m | 
| Chamber door | double-layer, with observation window, using explosion-proof glass. | 
| Test Area Material | SUS#304 Stainless Steel Plate | 
| External Material | SECC steel plate, processed by fine powder painting finish | 
| Power | 1ф220V , 50HZ | 